CATEGORY 6A S/FTP 4 PAIR DOUBLE JACKET EXTERNAL CABLE

Norden Category 6A S/FTP 4-Pair Double Jacket Cable exceeds Category 6A / Class EA specifications and is intended for external applications. It is tested up to a 500 MHz frequency range and designed to support 10 Gigabit Ethernet (10GBase-T) applications up to 100M .The cable provides exceptionally high pair balance, ensuring superior EMC (Electromagnetic Compatibility) by minimizing radiation, maximizing noise immunity, and providing excellent alien crosstalk performance compared to F/FTP (Foiled Twisted Pair) cabling systems.S/FTP (Shielded Foiled Twisted Pair) cables, which feature an overall braid shield and individual foil shields on each pair, are preferred for installations requiring enhanced alien crosstalk protection and improved data integrity in high-speed network environments.

Norden Category 6A S/FTP 4-Pair Double Jacket Cable exceeds Category 6A / Class EA specifications and is intended for external applications. It is tested up to a 500 MHz frequency range and designed to support 10 Gigabit Ethernet (10GBase-T) applications up to 100M .The cable provides exceptionally high pair balance, ensuring superior EMC (Electromagnetic Compatibility) by minimizing radiation, maximizing noise immunity, and providing excellent alien crosstalk performance compared to F/FTP (Foiled Twisted Pair) cabling systems.S/FTP (Shielded Foiled Twisted Pair) cables, which feature an overall braid shield and individual foil shields on each pair, are preferred for installations requiring enhanced alien crosstalk protection and improved data integrity in high-speed network environments.



PRODUCT CLASSIFICATION

Product SequencePremium
Product TypeTwisted Pair Cable


MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Solid Bare Copper

Conductor Size

23 AWG 

Conductor Construction

Solid

Insulation Material

Skin-foam-skin PE

Insulation Diameter

1.38 mm

Drain Wire( 1/0.40)

Tinned copper 

Colour Code

Per TIA/EIA 568-B 

Ind. Shield Material

Aluminum/polyester

Shield Overlap

≥25%

Conductor Unit lay-Up

Pairs 

Overall Shield Design

Braid 

Overall Shield Material

Tinned Copper, 0.10 mm

Braid Coverage

40%  

Total Number of Wires

Inner Jacket

LSZH (Low Smoke Zero Halogen)

Inner Jacket Thickness

0.50±0.05 mm 

Inner Diameter

7.50±0.30 mm

Outer Jacket

LDPE 

Outer Jacket Thickness & Ex. Diameter

0.5±0.05 mm, 8.6±0.30 mm


ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range

1 - 500 MHz

DC Resistance

93 Ω/km 

Max. Resistance Unbalance

≤4 %

Capacitance

5.6 nF/100m max.

Capacitance Unbalance

≤330 pF/100m  

Propagation Delay Skew

≤45 ns/100m

Velocity of Propagation

78 %

Dielectric Strength

1 KV/ 1 Min.

Max DC Loop Resistance

19.2Ω/100m 

Insulation Resistance

5 GΩ•km


TRANSMISSION PERFORMANCE


Frequency Data Table
Freq. MHz ATTN (dB/100m) RL (dB) NEXT (dB) ELFEXT (dB/100m) PS NEXT (dB/100m) PS ELFEXT (dB/100m)
4.003.8023.066.356.063.353.0
8.005.3024.561.849.958.846.0
10.005.9025.060.348.057.345.0
16.007.5025.057.243.954.240.9
20.008.4025.055.842.052.839.0
25.009.4024.354.340.051.337.0
31.2510.5023.652.938.149.935.1
62.5015.0021.548.432.145.429.1
100.0019.1020.145.328.042.325.0
200.0027.6018.040.822.037.819.0
250.0031.1017.339.320.036.317.0
300.0034.1017.338.118.535.115.5
500.0045.3017.334.814.031.811.0
Part NumberDescription
114-2022K504XCat6A S/FTP 4 Pair Double Jacket External Cable Inner LSZH /Outer LDPE

X: BK(Black)