The hybrid solar inverter intelligently prioritizes solar energy for primary usage, draws from battery storage when solar input is insufficient, and uses grid power only when necessary. By efficiently managing power from solar panels, batteries, and the utility grid, it delivers a exible, reliable, and energy-efficient solution- ideal for larger homes, small commercial buildings, and rural enterprises requiring consistent and cost-effective power
The hybrid solar inverter intelligently prioritizes solar energy for primary usage, draws from battery storage when solar input is insufficient, and uses grid power only when necessary. By efficiently managing power from solar panels, batteries, and the utility grid, it delivers a exible, reliable, and energy-efficient solution- ideal for larger homes, small commercial buildings, and rural enterprises requiring consistent and cost-effective power
| Model | NPS-0848H | NPS-1048H | NPS-1248H | |
| Rated Power | 8000VA/8000W | 10000VA/10000W | 12000VA/12000W | |
| Surge Power | 16000W | 20000W | 24000W | |
Input | Voltage | 230VAC | ||
| Selectable Voltage Range | 170~280VAC(UPS)/90-280VAC(APL)/184~253VAC(VDE) | |||
| Frequency Range | 50Hz/60Hz (Auto sensing) | |||
Output | Waveform | Pure sine wave | ||
| AC Voltage Regulation (Batt.Mode) | 230VAC±5% (Setting) | |||
| Inverter Efficiency (Peak) | 92% | |||
| Transfer Time | 10ms(UPS/VDE4105)/20ms(APL) | |||
Battery | Normal voltage | 48VDC | ||
| Floating Charge Voltage | 54.8VDC | |||
| Overcharge Protection | 60VDC | |||
Solar Charger & AC Charger | Maximum PV Array Open Circuit Voltage | 500VDC | ||
| Charging Algorithm | 3-Step (Flooded Battery, AGM/GEL/LEAD Battery), 4-Step (Li) | |||
| Maximum PV Array Power | 4000W*2 | 5000W*2 | 6000W*2 | |
| PV Array MPPT Voltage Range | 90-430VDC | |||
| Maximum Solar Charge Current | 120A | 150A | ||
| Maximum AC Charge Current | 120A | 150A | ||
| Maximum Charge Current | 120A | 150A | ||
| Physical features | Dimension (W*H*D) (mm) | 322*486 134 | ||
| Net Weight (kg) | 12.5 | |||
System speci cation | Humidity | 5% to 95% Relative humidity (Non-condensing) | ||
| Operation temperature range | 0°C to 50°C | |||
| Storage temperature | -15°C to 60°C | |||
| Certi cation and Standard | CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011) EN IEC62368-1:2020+A11:2020 CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011 | |||
| Part Number | Description | ||
| NPS-0848H | 8kW Hybrid Solar Inverter | ||
| NPS-1048H | 10kW Hybrid Solar Inverter | ||
| NPS-1248H | 12kW Hybrid Solar Inverter | ||