3Pair 18AWG, 4Core 18AWG, 2Core 18AWG, 4Core 16AWG Access Control Cable

This access control cable is suitable for use in automation, security systems, and lighting control applications. The cable is constructed with both paired and individual conductors with shielding; the conductors are insulated with polypropylene (PP) and both the inner and outer jackets are made of LSZH material.

This access control cable is suitable for use in automation, security systems, and lighting control applications. The cable is constructed with both paired and individual conductors with shielding; the conductors are insulated with polypropylene (PP) and both the inner and outer jackets are made of LSZH material. 

CONSTRUCTION & PHYSICAL CHARACTERISTICS

CharacteristicValue
Conductor Material
Bare Copper
Conductor Size (paired)
18AWG, 7/0.39±0.01
Conductor Size (4 core & 2 core)18AWG, 7/0.39±0.01 
Conductor Size (4 core) 16AWG, 19/0.30±0.01 
Insulation Material 
Polypropylene (PP)
Insulation Thickness (18 AWG)
0.25mm
Insulation Thickness (16 AWG)0.25mm
Insulation Material (18 AWG)
PVC
Insulation Diameter (18 AWG)
1.70±0.1mm
Insulation Diameter(16 AWG)
2.0±0.1mm
Shielding
AL/PET
Inner JacketLSZH 
Inner Jacket Thickness0.45mm
Inner Jacket Diameter

7.3±0.3mm(3Px18AWG)

5.1±0.2 mm(4Cx18AWG) 

4.4±0.2 mm(2Cx18AWG) 

5.9±0.2 mm(4Cx16AWG) 

Inner Jacket Color

Orange (3Px18AWG)

Blue (4CX18AWG)

White (2Cx18AWG)

Grey (4Cx16AWG) 

Drain Wire Material & Size
Tinned Copper, 7×0.2±0.01
Ripcord Yes
Outer Jacket
LSZH 
Outer Jacket Avg Thickness
0.50mm
Outer Jacket Dia
15.9±0.8mm
Outer Jacket Color
Yellow
 

ELECTRICAL & MECHANICAL CHARACTERISTICS

CharacteristicUnitValue
Nom. Capacitance Cond. to Cond. (3Px18AWG)pF/m159
Nom. Capacitance Cond. to Cond. (4CX18AWG) pF/m159
Nom. Capacitance Cond. to Cond. (2Cx18AWG) pF/m190
Nom. Capacitance Cond. to Cond (4Cx16AWG) pF/m226
Nom. Capacitance Cond. to Shield. (3Px18AWG)pF/m286
Nom. Capacitance Cond. to Shield. (4CX18AWG)pF/m286
Nom. Capacitance Cond. to Shield. (2Cx18AWG)pF/m342
Nom. Capacitance Cond. to Shield. (4Cx16AWG)pF/m407
Nom. Conductor DC Resistance @ 20°C (18 AWG) Ω/KM ≤21.9
Nom. Conductor DC Resistance @ 20°C (16 AWG) Ω/KM 13.7
Nom. Inner Shield DCR 20℃ (3Px18AWG)Ω/KM 53
Nom. Inner Shield DCR 20℃ (4CX18AWG) Ω/KM 62
Nom. Inner Shield DCR 20℃ (2Cx18AWG)Ω/KM 66
Nom. Inner Shield DCR 20℃ (4Cx16AWG) Ω/KM 61

Maximum Operating Voltage

V

300

Max. Recommended Current @ 25°C [18 AWG]

A

4

Max. Recommended Current @ 25°C [16 AWG]

A

5

Max. Recommended Pulling Tension

N

450

Minimum Bend Radius (Installation)

cm

16

Operating Temperature

°C

-20°C to+75°C

Installation Temperature
°C
0°C to +60°C

INSULATION COLOUR CODE

Individual PairColour

3 Pair

Black-Red, White- Green, Brown-Orange

4 Core Black, Red, White, Green
2 CoreBlack, Red
Part NumberDescription
9N-27B1A333X 3Pair 18AWG, 4Core 18AWG, 2Core 18AWG,4Core 16AWG  Access Control  Cable Inner & Outer  LSZH