Norden Category 6A F/FTP cables exceed Category 6A / Class EA specification. It is tested to 500 MHz frequency range and designed to support 10 Gigabyte applications to full 100 m.Extremely high pair-balance providing excellent EMC (Electro Magnetic compatibility). minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/FTP cabling systems. F/FTP (Twisted Pair - overall and individual Foil shield) cabling systems are installed for improved Alien Cross talk performance.
Norden Category 6A F/FTP cables exceed Category 6A / Class EA specification. It is tested to 500 MHz frequency range and designed to support 10 Gigabyte applications to full 100 m.Extremely high pair-balance providing excellent EMC (Electro Magnetic compatibility). minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/FTP cabling systems. F/FTP (Twisted Pair - overall and individual Foil shield) cabling systems are installed for improved Alien Cross talk performance.

| Product Sequense | Premium |
| Product Type | Twisted Pair Cable |
| Conductor Material | Bare Copper |
| Conductor Size | 23AWG |
| Conductor Construction | Solid |
| Insulation Material | Skin Foam Skin PE |
| Insulation O.D. | 1.35 mm nom. |
| Conductor Unit Identification | Solid/Stripe |
| Colour Code | Per TIA/EIA 568-B |
| Total Number of Wires | 8 |
| Drain Wire | Yes |
| Drain-Wire Material | Tinned Copper |
| In. Shield Material | 100 % Coverage |
| In .Shield Coverange | 100 % Coverage |
| Overall Shield Material | AL-PET Foil |
| Overall Foil Shield | Yes |
| Outer Jacket Material | LSZH |
| Outer Jacket Diameter | 7.50 ± 0.20mm |
| Frequency Range | 1 - 500 MHz |
| Max DC Resistance | <9.5 Ω / km |
| Max. Resistance Unbalance | <2% |
| Min. Insulation Resistance | 5000 MΩ x m |
| Mutual Capacitance | <56 pF / m |
| Capacitance Unbalance | 1600 pF / km |
| Impedance at 100 Mhz | 100 ± 5 Ω |
| Propagation Delay Skew | < 25 ns / 100 m |
| Velocity of Propagation | 76 % |
| Coupling Attenuation | 60 dB |
| Min. Impact | 10 Impact |
| Max. Tensile Strength | 95 N |
| Min. Crush Resistance | 1000 N/10 cm |
| Short Term Bend Radius | 60mm |
| Long Term Bend Radius | 30mm |
| Test Voltage | 1000 V |
| Operating Voltage | 125 V |
| Operating Temperature Rate | -20°C +70°C |
| Installation Temperature Rate | 0°C +50°C |
| Freq. MHz |
Attenuation dB/100m |
NEXT dB |
PS NEXT dB |
ACR (dB/100 m) |
PS-ACR (dB/100 m) |
ACRF (dB/100 m) |
PS.ACRF (dB/100 m) |
Return Loss (dB/100m) |
|---|---|---|---|---|---|---|---|---|
| 1 | 2.0 | 95 | 92 | 90 | 87 | 100 | 97 | 25 |
| 4 | 3.6 | 95 | 92 | 90 | 87 | 100 | 97 | 25 |
| 10 | 5.4 | 95 | 92 | 85 | 82 | 90 | 87 | 28 |
| 100 | 18.3 | 87 | 84 | 75 | 72 | 75 | 72 | 25 |
| 200 | 25.0 | 87 | 84 | 75 | 72 | 70 | 67 | 25 |
| 250 | 29.1 | 85 | 82 | 52 | 49 | 65 | 62 | 23 |
| 400 | 37.4 | 75 | 72 | 41 | 48 | 55 | 52 | 23 |
| 500 | 41.5 | 75 | 72 | 30 | 27 | 55 | 52 | 21 |
*Supplied cables meets Cat. 6A min. transmission requirements as per IEC 61156-5 Ed. 2
| Part Number | Description | Standard Length |
| 114-10008404X | Category 6A F/FTP 23 AWG 4 Pair Cable LSZH Dca | 305 / 500 m |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)