Category 7 S/FTP 4 Pair Cable LSOH

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. Norden Category 6A UTP cables are CPR Compliance to B2ca-s1a,d1,a1.The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR.It supports all Ethernet applications up to 1000 Base-T and CATV applications upto 862 Mhz.

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. Norden Category 6A UTP cables are CPR Compliance to B2ca-s1a,d1,a1.The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR.It supports all Ethernet applications up to 1000 Base-T and CATV applications upto 862 Mhz.


PRODUCT CLASSIFICATION

Product SequencePremium
Product TypeTwisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor MaterialBare Copper
Conductor Size23 AWG
Normal Conductor Diameter0.58±0.005 mm
Conductor ConstructionSolid
Insulation MaterialSFS PE
Insulation O.D.1.35 mm nom.
Conductor Unit IdentificationSolid/Stripe
Color CodePer TIA/EIA 568-B
Ind. Shield MaterialAluminium/Polyester Foil
Ind. Shield Design100 % Coverage
Conductor Unit Lay-UpPairs
Overall Braid Shield MaterialTinned Copper 0.10 mm
Braid CoverageMore than 40 %
Drain-Wire MaterialN/A
Outer Jacket MaterialLSOH
Outer jacket thickness & Ex. Diameter0.55±0.05 mm, 7.9±0.5 mm
Rip cordYes
Total Number of Wires8
Outer Jacket ColorPer Requirement
MarkingPer Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range1 - 1000 MHz
Impedance100 Ω
Impedance100 Ω
Max. DC Resistance73 Ω/km @ 20 °C
Max. Resistance Unbalance2 %
Capacitance Unbalance1.2 pF/m max.
Velocity of Propagation78 % nom
Propagation Delay Skew25 ns/100m max.
Dielectric Strength1.5 kV/minute
Dielectric Strength to Shield1.5 kV/minute
Min. Insulation Resistance5 GΩ•km
Coupling Attenuation85 db min @ 30-100 MHz 85-20log (f/100) @100-600 MHz
Max. Tensile Strength - Short Term130 N
Min. Bend Radius60 mm
Operating Temperature Range-35 °C +65 °C

TRANSMISSION PERFORMANCE

Cat. 7 Screened Horizontal Cables*
Freq.
MHz
Attenuation
dB/100m @ 20ºC
NEXT
dB
PSNEXT
dB
RL
dB
ACR
dB
ELFEXT
dB
PSELFEXT
dB
12.080.077.020.078.079.076.0
43.780.077.023.076.378.875.8
105.780.077.025.074.376.473.4
207.480.077.025.072.673.370.3
31.2510.0978.875.823.868.870.167.1
10018.872.469.420.153.665.062.0
15022.569.666.618.847.163.760.7
20026.567.964.918.041.462.259.2
25029.066.563.517.337.560.857.8
30033.665.362.316.431.758.655.6
40038.664.061.016.425.455.952.9
50044.962.359.316.417.453.451.4
60048.760.857.816.412.150.147.1

Part NumberDescriptionStandard Length
115-10009504XCategory 7 S/FTP 4 Pair Cable LSOH305 mtr

 

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)