NORDEN External Telephone Cables are designed to connect telephone and communication equipment reliably. These cables can also be used for other communication, control systems, or low-level signalling. With PE Insulation, PE Inner, and an LSZH Outer, the cables meet high performance standards. They are ideally suited for both underground and direct-buried installations
NORDEN External Telephone Cables are designed to connect telephone and communication equipment reliably. These cables can also be used for other communication, control systems, or low-level signalling. With PE Insulation, PE Inner, and an LSZH Outer, the cables meet high performance standards. They are ideally suited for both underground and direct-buried installations

Conductor | Single solid bare copper |
Insulation | PE |
Screening | Aluminium tape |
Braiding | Copper wire braid (65% coverage) |
Inner Sheath | PE |
Armouring | Steel wire |
Outer Jacket | LSZH |
| Characteristic | Value | ||
| 2 Core | 4 Pair | 50 Pair | |
| Conductor Size | 16AWG(1.29mm) | 18AWG (1.0mm | 18AWG (1.0mm) |
| Nom. Insulated Diameter(mm) | 2 | 1.8 | 1.8 |
| Inner Sheath Diameter(mm) | 5 | 11.5 | 137 |
| Inner Sheath Thickness(mm) | 0.8 | 1.2 | 1.5 |
| Steel Wire Diameter(mm) | 0.9 | 1.25 | 1.6 |
| Outer Sheath Diameter(mm) | 9.4 | 17.6 | 45 |
| Outer Sheath Thickness(mm) | 1.3 | 1.6 | 2 |
| Min. Bending Radius | 12*OD | ||
| Operating Temperature | -5 °C to +70 °C | ||
| Characteristic | Unit | Value |
| Peak operating voltage | V | 300 |
| Test voltage wire/wire | V | 800 |
| Test voltage wire/shield | V | 800 |
| Attenuation at 800 Hz | dB/km | 1.1 |
| Insulation- specific volume resistance | MΩ/km | 100 |
| Pairs | Primary | Secondary |
| 1 | White | Blue |
| 2 | White | Orange |
| 3 | White | Green |
| 4 | White | Brown |
| 5 | White | Grey |
| 6 | Red | Blue |
| 7 | Red | Orange |
| 8 | Red | Green |
| 9 | Red | Brown |
| 10 | Red | Grey |
| 11 | Black | Blue |
| 12 | Black | Orange |
| 13 | Black | Green |
| 14 | Black | Brown |
| 15 | Black | Grey |
| 16 | Yellow | Blue |
| 17 | Yellow | Orange |
| 18 | Yellow | Green |
| 19 | Yellow | Brown |
| 20 | Yellow | Gray |
| 21 | Violet | Blue |
| 22 | Violet | Orange |
| 23 | Violet | Green |
| 24 | Violet | Brown |
| 25 | Violet | Grey |
| 26 | White | Blue |
| 27 | White | Orange |
| 28 | White | Green |
| 29 | White | Brown |
| 30 | White | Grey |
| 31 | Red | Blue |
| 32 | Red | Orange |
| 33 | Red | Green |
| 34 | Red | Brown |
| 35 | Red | Grey |
| 36 | Black | Blue |
| 37 | Black | Orange |
| 38 | Black | Green |
| 39 | Black | Brown |
| 40 | Black | Gray |
| 41 | Yellow | Blue |
| 42 | Yellow | Orange |
| 43 | Yellow | Green |
| 44 | Yellow | Brown |
| 45 | Yellow | Gray |
| 46 | Violet | Blue |
| 47 | Violet | Orange |
| 48 | Violet | Green |
| 49 | Violet | Brown |
| 50 | Violet | Gray |
| Part Number | Description | Conductor Diameter (mm) |
| 212-18162002 | 2 Core External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1.29 |
| 212-18122004 | 4 Pair External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1 |
| 212-18122050 | 50 Pair External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1 |