Norden Category 6 S/UTP cables exceed Category 6 / Class E requirements. They are tested up to 250 MHz and are designed to support Gigabit Ethernet applications, including 1000Base-T and 1000Base-TX, over a channel length of up to 100 m. The cables offer excellent pair balance, ensuring superior EMC (Electromagnetic Compatibility), reduced emissions, and improved noise immunity. The overall braid screen provides effective protection against external interference, ensuring stable transmission performance and minimizing crosstalk. S/UTP cabling systems are ideal for environments that require additional protection against external noise, while not using individual pair shielding.
Norden Category 6 S/UTP cables exceed Category 6 / Class E requirements. They are tested up to 250 MHz and are designed to support Gigabit Ethernet applications, including 1000Base-T and 1000Base-TX, over a channel length of up to 100 m. The cables offer excellent pair balance, ensuring superior EMC (Electromagnetic Compatibility), reduced emissions, and improved noise immunity. The overall braid screen provides effective protection against external interference, ensuring stable transmission performance and minimizing crosstalk. S/UTP cabling systems are ideal for environments that require additional protection against external noise, while not using individual pair shielding.

| Product Sequence | Premium |
| Product Type | Twisted Pair Cable |
| Conductor Material | Solid Bare Electrolytic Grade Copper |
| Conductor Size | 23AWG |
| Conductor Construction | Solid |
| Insulation Material | HDPE |
| Insulation Diameter | 1.08 ± 0.05mm |
| Conductor Unit Identification | Solid/Stripe |
| Rip Cord | No |
| Drain Wire | Yes |
| Colour Code | Per TIA/EIA 568-B |
| Conductor Unit lay-Up | Pairs |
| Overall Shield Design | Braid |
| Overall Shield Material | Annealed Tinned Copper |
| Braid Coverage | >38% |
| Total Number of Wires | 8 |
| Outer Jacket | LSZH |
| Outer Jacket Thickness & Ex. Diameter | 0.6mm, 7.0 ± 0.30mm |
| Outer Jacket Colour | Per Requirement |
| Marking | Per Requirement |
| Frequency Range | 1 - 250 MHz |
| Impedance | 100 Ω ±15 |
| DC Resistance | 93.8Ω/km |
| Max. Resistance Unbalance | 5 % |
| Capacitance | 5.6 nF/100m max. |
| Capacitance Unbalance | 330 pf/100m Max. |
| Worst Case Cable Skew | 45 ns/100m max. |
| Propagation Delay Skew | 45 ns/100m max. |
| Velocity of Propagation | 69 % |
| Dielectric Strength | 1KV/3 Sec. |
| Min. Insulation Resistance | 5 GΩ•km |
| Max. Tensile Strength | 100N |
| Min. Bend Radius | 8XOD |
| Operating Temperature Range | -20°C +75 °C |
Cat. 6 screened Pair Horizontal Cables*
*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
| Freq. MHz | Attenuation dB/100m @ 20°C | NEXT dB min. | PSNEXT dB min. | ACRF (dB@100 m) min. | PS.ACRF (dB@100 m) min | Return Loss (dB/100m) |
|---|---|---|---|---|---|---|
| 1 | 2.1 | 65 | 62 | 63.3 | 60.3 | 19 |
| 4 | 4 | 63 | 60.5 | 51.2 | 48.2 | 19 |
| 8 | 5.7 | 58.2 | 55.6 | 45.2 | 42.2 | 19 |
| 10 | 6.3 | 56.6 | 54 | 43.3 | 40.3 | 19 |
| 16 | 8 | 53.2 | 50.6 | 39.2 | 36.2 | 18 |
| 20 | 9 | 51.6 | 49 | 37.2 | 34.2 | 17.5 |
| 25 | 10.1 | 50 | 47.3 | 35.3 | 32.3 | 17 |
| 31.25 | 11.4 | 48.4 | 45.7 | 33.4 | 30.4 | 16.5 |
| 62.5 | 16.5 | 43.4 | 40.6 | 27.3 | 24.3 | 14 |
| 100 | 21.3 | 39.9 | 37.1 | 23.3 | 20.3 | 12 |
| 200 | 31.5 | 34.8 | 31.9 | 17.2 | 14.2 | 9 |
| 250 | 35.9 | 33.1 | 30.2 | 15.3 | 12.3 | 8 |
| Part Number | Description | Standard Length |
| 113-10002904X | Category 6 S/UTP 23AWG 4 Pair Cable LSZH | 305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)