CAT 6 UTP cable consists of eight copper conductors, with two conductors twisted together to form one pair. A total of four twisted pairs are laid up and separated by a special cross-separator, which enhances electrical performance by reducing crosstalk. The four pairs are assembled together and covered with an extruded PVC inner sheath, providing mechanical stability. This is followed by aluminium armouring, offering protection against mechanical damage and rodent attack. The overall outer sheath is UV-resistant LSZH (Low Smoke Zero Halogen), making the cable suitable for outdoor installations with enhanced fire safety and environmental resistance.
CAT 6 UTP cable consists of eight copper conductors, with two conductors twisted together to form one pair. A total of four twisted pairs are laid up and separated by a special cross-separator, which enhances electrical performance by reducing crosstalk. The four pairs are assembled together and covered with an extruded PVC inner sheath, providing mechanical stability. This is followed by aluminium armouring, offering protection against mechanical damage and rodent attack. The overall outer sheath is UV-resistant LSZH (Low Smoke Zero Halogen), making the cable suitable for outdoor installations with enhanced fire safety and environmental resistance.
IEEE 802.af and IEEE 802.3at for PoE applications
EIA/TIA 568-D.2
Conductor | Stranded Bare Electrolytic Grade Copper |
Conductor Size | 24 AWG (7/0.195 ± 0.015MM) |
Wire Insulation | HDPE |
Pairing | Twisted into Two Core |
No.of Pair | 4 nos, Each pair Twisted |
Number of Insulated Conductors | 8 |
Colour Code Of Pairs | Blue x White, Orange x White, Green x White, Brown x White |
Inner Sheath | PVC |
Colour of Inner Sheath | Natural White |
Armouring | Aluminium Wire |
Outer Sheath | LSZH with UV Properties |
Colour Of outer Sheath | Black |
Cable O.D. | 9.80 ± 0.50 mm |
Standard Surface Marking | Includes Norden P/N, cable description |
Cross Filler | Yes |
Operating Temperature | - 20 to +75C |
Characteristic Impedance | 100 ± 15% Ohms |
Conductor Resistance | Max. 93.8 Ω /km @ 20°C |
Resistance Unbalance | Max. 5% |
Mutual Capacitance | Max. 5.6 nf/100 mtr |
Pair to Ground Capacitance Unbalance | Max. 330 pf/100 mtr |
Normal Velocity of Propagation | 69% |
Worst Case Cable Skew | Max. 45 ns/100 mtr |
Worst Cable Skew | 45 ns/100 mtr |
| Freq. (MHz) | ATT(dB/100m) max. | NEXT(dB) min. | PS NEXT(dB) min. | ACRF (dB@100m) min. | PS ACRF (dB@100m) min. | Return Loss (dB) min. |
|---|---|---|---|---|---|---|
| 1 | 2.1 | 65.0 | 62.0 | 63.3 | 60.3 | 19.0 |
| 4 | 4.0 | 63.0 | 60.5 | 51.2 | 48.2 | 19.0 |
| 8 | 5.7 | 58.2 | 55.6 | 45.2 | 42.2 | 19.0 |
| 10 | 6.3 | 56.6 | 54.0 | 43.3 | 40.3 | 19.0 |
| 16 | 8.0 | 53.2 | 50.6 | 39.2 | 36.2 | 18.0 |
| 20 | 9.0 | 51.6 | 49.0 | 37.2 | 34.2 | 17.5 |
| 25 | 10.1 | 50.0 | 47.3 | 35.3 | 32.3 | 17.0 |
| 31.25 | 11.4 | 48.4 | 45.7 | 33.4 | 30.4 | 16.5 |
| 62.5 | 16.5 | 43.4 | 40.6 | 27.3 | 24.3 | 14.0 |
| 100 | 21.3 | 39.9 | 37.1 | 23.3 | 20.3 | 12.0 |
| 200 | 31.5 | 34.8 | 31.9 | 17.2 | 14.2 | 9.0 |
| 250 | 35.9 | 33.1 | 30.2 | 15.3 | 12.3 | 8.0 |
| Part Number | Description | Length |
NC45-37101X | CAT 6 U/UTP Double Jacket Aluminium Wire Armoured Patch Cord PVC/UV- LSZH-01mtr | 01m |
| NC45-37102X | CAT 6 U/UTP Double Jacket Aluminium Wire Armoured Patch Cord PVC/UV-LSZH-02mtr | 02m |
| NC45-37105X | CAT 6 U/UTP Double Jacket Aluminium Wire Armoured Patch Cord PVC/UV- LSZH-05mtr | 05m |
| NC45-37110X | CAT 6 U/UTP Double Jacket Aluminium Wire Armoured Patch Cord PVC/UV-LSZH-10mtr | 10m |
| NC45-37120X | CAT 6 U/UTP Double Jacket Aluminium Wire Armoured Patch Cord PVC/UV-LSZH-20mtr | 20m |