Norden's Ultra power series 10-20 kVA UPS is an online double conversion UPS that features three-phase in both input and output and an output power factor of 0.9 .This tower type model Features a high power density design with parallel redundancy and ECO mode mode operation for power saving.
Norden's Ultra power series 10-20 kVA UPS is an online double conversion UPS that features three-phase in both input
and output and an output power factor of 0.9 .This tower type model Features a high power density design with parallel
redundancy and ECO mode mode operation for power saving.
| Model | CN93310U | CN93315U | CN93320U | |
Capacity | kVA | 10 | 15 | 20 |
Watts | 9kW | 13.5kW | 18kW | |
Input | Normal Voltage | 380/400/415Vac (3Ph+N+PE)
| ||
| Operating voltage range | 305~478Vac(Full load); 208~478Vac(50% load)
| |||
| Harmonic distortion(THDi) | <3%(linear load) | |||
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) | |||
| Power factor | ≥0.99 | |||
| Bypass voltage range | 220Vac Max.Voltage:+25% (optional +10%,+15%,+20%) 230Vac Max.Voltage:+20%(optional +10%,+15%)
240Vac Max.Voltage:+15%(optional +10%) Min.Voltage:-45%(optional -20%,-30%) | |||
| Bypass Frequency range | Frequency synchronize tracing range:±10% | |||
| Generator input | Support | |||
Output | Rated voltage | 380/400/415Vac (3Ph+N+PE) | ||
| Power factor | 0.9 | |||
| Voltage regulation | ±1% | |||
| Frequency Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) | |||
| Frequency Bat. mode | 50/60(±0.1)Hz | |||
| Crest factor | 3:1 | |||
| Harmonic distortion (THDv) | ≤2% with linear load, ≤5% with non-linear load | |||
| Efficiency | 94.5% | |||
| Output Waveform | Pure SineWave | |||
Battery | Battery voltage | ±96/108/120Vdc(16/18/20pcs) | ||
| Charging current (Charging current can be set according to the battery capacity installed) |
14A |
16A |
18A |
|
System Features | Transfer time | Mains to battery:0ms; Inverter to bypass:0ms
| ||
| Overload Line mode | ≤110%,last 60min; ≤125%,last 10min; ≤150%,last 1min;>150% turn to bypass Immediately
| |||
| Overload Bypass mode | ≤110%,last 10min; ≤125%,last 1min; ≤150%,last 5s; >150% turn to bypass Immediately
| |||
| Backfeed Protection | Support | |||
| Alarm | Overload, utility abnormal, UPS fault, battery low, etc | |||
| Protection | Short circuit, overload, over-temperature, battery low, fan fault alarm | |||
| Communication | USB, RS232, RS485, Parallel port,dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) | |||
Environment | Operating temperature | 0~40°C | ||
| Storage temperature | -25~55°C | |||
| Humidity range | 0~95% (Non-condensing) | |||
| Altitude | <1500m | |||
| Noise level | <55dB | <58db | ||
Physical | Dimension WxDxH(mm) | 250x580x655 | ||
| Net Weight (kg) | 35 | 39 | 40 | |
Standards | Safety | CE; IEC/EN62040-1,IEC/EN62477-1
| ||
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | |||
| Part Number | Description | ||
| CN93310U | 10kVA Double Conversion Transformer-less UPS | ||
| CN93310U-5L | 10kVA Double Conversion Tower Type 3/3 UPS with 7inch LCD display (External Battery) | ||
| CN93315U | 15kVA Double Conversion Transformer-less UPS | ||
| CN93315U-5L | 15kVA Double Conversion Tower Type 3/3 UPS with 7inch LCD display (External Battery) | ||
| CN93320U | 20kVA Double Conversion Transformer-less UPS | ||
| CN93320U-5L | 20kVA Double Conversion Transformer-less 3/3 UPS with 5 Inch LCD Display (External Battery) | ||
| Part Number | Description | ||
| CNS01 | SNMP Card | ||
